0 items in your basket
Total £ 0.00 EX VAT
SHOPS
Special Buys/Offers
Rapid Merchandise Shop
PATON Shop
GoGrid Shop
GasiQ Shop
CK Shop
Furick TIG Shop
GPPH Shop
Kemppi Shop
Spiderhand Shop
Optrel Shop
3M Shop
Plymovent Fume Extraction
Miller Shop
Elga Shop
CEPRO Shop
Bohler Welding Shop
SFE Shop
Hypertherm Shop
Lincoln Electric Shop
ESAB Shop
Fronius Shop
HMT Shop
Gullco Shop
FEIN Shop
SAIT Shop
Harris Shop
FANUCI & FALCON Shop
Jackson Safety Shop
Key Plant Automation Shop
Orbitalum Shop
Bessey Shop
Bester Shop
EWM Shop
MACHINES
Welding Machine Offers
Arc Welders
MIG Welders
TIG Welders
Plasma Cutters
Air Compressors
Engine Driven Welders
Battery Power Supplies
Generators
Fume Extraction
Sub Arc Machines
Weld Positioning Equipment
Cutting Equipment
Spot Welders
Stud Welders
Used Machines
LC Laser Shop
ARC
MMA Electrodes
Cable Sets
Earth Clamps
Electrode Holders
Cable Connectors
Welding Cable
Welding Helmets
Arc Accessories
Rod Ovens
Learning
Exothermic Cutting
Chemical Aids
Gouging
MIG
MIG Filler Wire
MIG Torches & Parts
Site Wire Feeders
MIG Regulators
Ceramic Backing Tiles
MIG Accessories
TIG
TIG Torches
TIG Torch Parts
Tungsten Electrodes
TIG Filler Wire
Machine Remotes
TIG Accessories
Cold Wire Feeders
TIG Gauntlets
Tungsten Sharpening
Weld Cleaning
Gas Purging Tools
LASER
Laser Welders
Laser Cleaners
Laser Accessories
PLASMA
Plasma Torches
Plasma Torch Consumables
Lincoln Cutting Tables
GAS
Cutting & Welding Outfits
Gas Regulators
Flashback Arrestors
Gas Hoses & Fittings
Gas Torches
Gas Cutting Nozzles
Gas Welding & Heating Nozzles
Gas Accessories
Gas Welding & Brazing Rods
Gas Bottle Trolleys
Gas Cutting Machines
Quick Action Couplings
Regulator Accessories
Gas Analysers
SAFETY
Helmet Spares
Air Fed Welding Helmets
Swiss Air System
Goggles
Welding Blankets
Spectacles
Visors
Welding Curtains
Ear Protection
Safety Helmets
Monkey Masks
Gloves
Caps & Hoods
Leather Welding Clothing
Overalls
Weldline Female PPE
Disposable Masks & Respirators
WORKSHOP
Build your own GPPH Welding Table
Magnetic Drilling
Rapid Pipe Shop
Bevelling Machines
Automation
Metal Markers
Inspection Equipment
Pipework Equipment
Site Equipment
Exact Pipe Cutting Machines
Welding Rotators
Welding Tables
Bandsaws & Blades
TORCH &MACHINE SPARES
Pipe Cutting Machine Accessories
Parts for CO2 Laser
Kemppi MIG Parts
Machine Parts
Plasma Welding Torches
Water Coolers
Binzel MIG Parts
Tungsten Grinder Parts
WIRE, FLUX & RODS
Brazing Flux
Sub Arc Wire & Flux
ABRASIVES
3M Abrasives
SAIT Abrasives
Spectre Abrasives
Other Brand Abrasives
Backing Pads
Finishing & Polishing Products
Wire Brushes
Abrasive Belts
TOOLS
Angle Grinders
Right Lines Tool Offers
Magnetic Tools
Welding Clamps
Pipe Fit Up Tools
Site Storage
Orbitalum Pipe Machines
Orbitalum GF Sawblades
KNOWLEDGECENTRE
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Spare parts for the Weldline Flip Air LS (Silver) Welding Helmet with Zephyr LS Air Flow System. For the Older Flip Air (Green Helmet) Unit parts Click Here
Filters, batteries, hoses, straps and helmet parts for a powered air respirator welding helmet, and how to choose and look after them.
The HSE lists the key maintenance tasks for powered respirators as changing replaceable filters, cleaning the device, checking the straps for damage and checking the battery charge and flow rate. In a welding helmet system that usually means the main particle filter, any pre-filter, the battery, the breathing hose and its cover, the belt or shoulder strap, and the helmet's own seals, lenses and headgear.How quickly each wears depends on the work, the fume level and the maker's instructions, so use the manual as your guide.
Match it to the type the maker specifies for your blower unit, using the manual or the marking on the old filter. Particle filters are marked P1 (low efficiency), P2 (medium) and P3 (high), according to HSE guidance. Welding fume is a particulate hazard. For arc welding, HSE welding guidance recommends powered or supplied-air equipment with an assigned protection factor of at least 20, and it names P3 as the filter level for half masks.A particle filter does not protect against gases or vapours. If your work produces them, ask the maker or your risk assessor about a combined filter before choosing.
There is no single interval. The HSE says replaceable filters have a limited capacity and can clog, so they should be changed as the manufacturer instructs and whenever they are damaged, visibly contaminated or when airflow drops.How quickly a filter loads depends on the amount of welding, the fume produced, the material and the working conditions. Low airflow or a warning from the unit is a sign to stop and check the filter and battery. Fit identical filters together if the unit takes more than one, and change them all at the same time. Never run the unit without the filter fitted.
A pre-filter is a coarser layer that catches larger particles such as dust and spatter debris before they reach the main filter, so the main filter lasts longer and stays cleaner. It is usually changed more often than the main filter.It is an addition to the main filter and not a substitute for it: the main particle filter is what provides the stated protection. Fit the pre-filter the way the manual shows, because a loose or badly positioned one can restrict airflow or let debris past. Follow the maker's advice on when to change it.
The HSE says to make sure battery-powered RPE is fully charged before use and to check the battery charge as part of regular maintenance. Charge it with the charger supplied or specified for it, store and charge it as the manual describes, and replace it when it no longer lasts a full shift or no longer charges properly.Batteries of different capacities or styles are often made for the same unit, so check that the type you order is listed for your blower. Spare batteries are useful for long shifts, but always check the airflow after fitting one.
Always check that the fan is providing enough airflow before you use the device, following the maker's airflow check in the manual. The HSE guidance is clear that you should never keep working if the fan stops or the flow rate falls: leave the work area immediately. If your unit has a low-flow warning, treat it the same way.Then check for a blocked or loaded filter, a flat battery, a kinked or damaged hose or a loose connection. Do not return to work until the fault is corrected and the airflow check passes. If you cannot find the fault, have the unit examined by a competent person.