Plain answers on choosing and looking after core drilling cutters, motor spares, attachments and carry accessories for industrial drilling tools.
How do I get the most life out of a core drilling cutter?

Use cutting fluid or paste made for metal cutting every time. Lubricant greatly extends cutter life, and some manuals say the cutter must never run dry. Feed with steady, even pressure, easing off at the start and end of the cut. Leaning hard on the machine because the feed is slow is a common cause of dulling.
If the cutter jams, stop feeding, disconnect from the supply and free it by turning the arbor by hand rather than switching the motor on and off. Check the cutter before every use and do not use one that is damaged or blunt. Clear chips after use, store cutters so the teeth are not knocked, and check any pilot pin is straight and moves freely. Follow the maker's speed and feed advice for the material.
What does the workpiece need to be like for the magnet to hold?

Holding force depends on the thickness and condition of the steel. The best hold is on soft steel of enough thickness, and the holding force falls progressively as the steel gets thinner. A steel packing plate under the magnet or the work makes up the thickness. The minimum thickness differs widely between machines, so check your manual.
Clean the surface first, removing spatter, rust, dirt, grease and metal chips from the base. The magnet only holds while the power is on, and a power loss or overload removes the holding force, so always use the safety strap and check any magnet indicator before you start drilling.
Is the safety strap really needed, and what about medical implants?

Yes. Use the strap supplied to secure the machine to the work. It matters most on vertical, sloping and overhead work, and on scaffolds, because a power failure can make the machine fall or swing. Check the strap for wear or damage before each use and do not use a damaged one.
The base magnet is strong and its field can interfere with some implanted medical devices, such as pacemakers. Anyone with an implant should get advice from their doctor or the device maker before using the machine or working close to it, and should read the manual. Keep bystanders in mind and follow your risk assessment.
What electrical checks should I make before using the drill?

Before each use, switch off and unplug, then look over the supply cable, plug and casing. Check the cable and equipment before use, and remove damaged or faulty equipment from use without delay. It should be repaired by a competent person or disposed of.
How often equipment needs a formal inspection or test depends on the risk, including whether it is used in a harsh environment. Drilling tools in workshops or on site are likely to need more than the minimum, so base your checks on your risk assessment and the maker's manual.