Fronius Magic Cleaner Options FAQs
Accessories for an electrochemical weld cleaning unit for stainless steel: electrodes, holders, electrolyte, tanks and earth cables, and how to choose and use them safely.
Does electrochemical cleaning need a chemical risk assessment?

Yes. Electrochemical cleaning is the main chemical alternative to hydrofluoric acid pickling paste, and although the acids are milder, a chemical risk assessment is still required, including whether PPE is needed. The electrolyte is an acid-based chemical, so look at the product's safety data sheet, decide what controls and PPE are needed, and make sure everyone using it is trained.
The assessment should cover storage, handling and refilling, skin and eye protection, ventilation, first aid, spills and disposal of used cloths and rinse water. Follow the unit maker's instructions as well.
What are the alternatives to electrochemical cleaning, and when might I use them?

There are several ways to deal with discoloured stainless welds, and a less hazardous method is preferable to pickling paste. Mechanical options include grinding, buffing, blasting and brushing with a stainless brush kept only for stainless. Pickling paste is a chemical route, and it can contain very hazardous acids. Electrochemical cleaning is another route, and its contact pad may reach welds that mechanical methods cannot.
Mechanical methods can be less effective at removing the chromium-depleted layer than pickling, and brushing or blasting can embed particles or roughen the surface. Which method suits you depends on the stainless grade, the finish and corrosion performance you need, and the hazards you can control, so check your specification.
How should I dispose of used cloths, residue and rinse water?

Clean up spills straight away, put used cloths in a clearly marked container and dispose of them in line with your local waste authority's guidance. Acidic rinse water should not enter the public drain without treatment and may need to be neutralised, so consult the local water company first.
These are sensible principles for any acid-based cleaner. Check the electrolyte's safety data sheet and your risk assessment for disposal instructions, and never pour used liquid down a drain without checking.
What should I check on the earth (ground) cable and clamp before cleaning?

The cleaning circuit needs a sound return path through the workpiece. Leads, connectors and clamps should be checked at regular intervals for fitness for use, and damaged or worn parts should be repaired or replaced. Look for cracked insulation, loose or corroded connections and damaged plugs.
Clamp firmly to clean bare metal on the workpiece, removing rust or paint locally so the clamp makes good contact, and keep the clamp close to the area being cleaned. Cable size, plug type and current rating are specific to the unit, so use the lead the manual specifies and do not swap it for a different cable without the maker's approval.