Fronius Magic Cleaner Options FAQs
Accessories for an electrochemical weld cleaning unit for stainless steel: electrodes, holders, electrolyte, tanks and earth cables, and how to choose and use them safely.
Does electrochemical cleaning need a chemical risk assessment?

Yes. Electrochemical cleaning is the main chemical alternative to hydrofluoric acid pickling paste, and although the acids are milder, a chemical risk assessment is still required, including whether PPE is needed. The electrolyte is an acid-based chemical, so look at the product's safety data sheet, decide what controls and PPE are needed, and make sure everyone using it is trained.
The assessment should cover storage, handling and refilling, skin and eye protection, ventilation, first aid, spills and disposal of used cloths and rinse water. Follow the unit maker's instructions as well.
What eye and hand protection should I wear when using electrolyte?

Electrolyte is acid based, so protect your eyes, skin and clothing. Liquid can get past safety glasses, so do not rely on glasses alone, especially if they are not close fitting. A full-face shield is recommended for acid work, and your risk assessment will decide what you need.
For gloves, choosing the right material is complicated, so check the electrolyte safety data sheet and ask the glove or chemical supplier for test data for your substance. Check gloves for holes or cuts before use, and keep water for washing close by.
Why is heat tint on stainless steel worth removing?

Heat tint is the coloured oxide layer that forms on the weld and the heat-affected zone next to it. The scale is not very protective and leaves the surface beneath it depleted in chromium, so heat-tinted surfaces are more susceptible to pitting and crevice corrosion.
To restore corrosion resistance, both the scale and the chromium-depleted layer beneath it need to be removed by post-weld cleaning. How much tint is acceptable depends on the application and specification. An efficient back purge during welding also helps to minimise heat tint in the first place.
What should I check on the earth (ground) cable and clamp before cleaning?

The cleaning circuit needs a sound return path through the workpiece. Leads, connectors and clamps should be checked at regular intervals for fitness for use, and damaged or worn parts should be repaired or replaced. Look for cracked insulation, loose or corroded connections and damaged plugs.
Clamp firmly to clean bare metal on the workpiece, removing rust or paint locally so the clamp makes good contact, and keep the clamp close to the area being cleaned. Cable size, plug type and current rating are specific to the unit, so use the lead the manual specifies and do not swap it for a different cable without the maker's approval.