WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : 0700000503  

    ESAB G30 Large Inner Visor DIN 3 AS
    0700000503

    £19.50  EX VAT
    SSP Suggested Selling Price = £26.00  YOU SAVE £6.50

    Related Items

    ESAB G30 Air Parts FAQs

    Spares for a flip-front welding helmet prepared for a fresh-air supply: air-duct headgear, visors, shell and sweatbands, and how to check and look after them.

    What is headgear with an air duct, and how does it differ from ordinary headgear?icon-minus-redicon-plus-red

    Headgear with an air duct is a different part from standard headgear. On a helmet designed for a fresh-air supply, the headgear includes a duct that carries air from the supply into the helmet, so ordinary headgear will not do the same job.

    Check your helmet's manual and parts list for the correct part, and ask the maker or your supplier if you are unsure. Fit it exactly as instructed, and check it for damage and secure connections before each use, because a loose or damaged duct connection can reduce the air reaching your breathing zone.

    What should I check on the helmet before each use?icon-minus-redicon-plus-red

    Powered and fresh-air helmets are respiratory protective equipment (RPE). Users should check their RPE every time they use it, following the maker's instructions, and any problem should be reported to your supervisor rather than carrying on working.

    In practice, check the visors for cracks, pitting or spatter, the headgear and duct for damage and secure connections, and the face seal for tears. Check that hoses are connected properly and that battery-powered equipment is fully charged. Then confirm that air is actually reaching the helmet, using the method in your manual. Different helmets and supplies have different checks and flow figures, so use your own manual's pre-use routine.

    Do I need a face-fit test for a helmet like this?icon-minus-redicon-plus-red

    It depends on whether the facepiece is tight-fitting or loose-fitting. Tight-fitting facepieces rely on a seal to the face, so the wearer needs a fit test for that device and must be clean shaven where the seal sits.

    Loose-fitting facepieces, such as hoods, helmets and visors, rely on enough clean air being supplied to keep contaminants out. They are only available as powered respirators or breathing apparatus, and fit testing is not required for them. Most welding helmets with an air supply are loose-fitting, but check your manual and your employer's risk assessment to confirm how yours is classed. If yours is classed as tight-fitting, a fit test is needed.

    What wears on the duct, face seal and helmet parts, and how do I check them?icon-minus-redicon-plus-red

    Check the air duct and any breathing tube for splits, kinks, loose connections and dirt inside, and the face seal for tears or stiffening. Follow your manual for cleaning, because some tubes must not be rinsed, immersed or treated with solvents. Replace damaged parts rather than repairing them yourself, and use the parts your manual specifies.

    Reusable RPE should be thoroughly examined and, where appropriate, tested at least monthly, or at least every three months if it is only used occasionally, with a check before each use. Results should be recorded and kept for at least five years. Between those checks, look the equipment over every time you use it.