0 items in your basket
Total £ 0.00 EX VAT
SHOPS
Special Buys/Offers
Rapid Merchandise Shop
PATON Shop
GoGrid Shop
GasiQ Shop
CK Shop
Furick TIG Shop
GPPH Shop
Kemppi Shop
Spiderhand Shop
Optrel Shop
3M Shop
Plymovent Fume Extraction
Miller Shop
Elga Shop
CEPRO Shop
Bohler Welding Shop
SFE Shop
Hypertherm Shop
Lincoln Electric Shop
ESAB Shop
Fronius Shop
HMT Shop
Gullco Shop
FEIN Shop
SAIT Shop
Harris Shop
FANUCI & FALCON Shop
Jackson Safety Shop
Key Plant Automation Shop
Orbitalum Shop
Bessey Shop
Bester Shop
EWM Shop
MACHINES
Welding Machine Offers
Arc Welders
MIG Welders
TIG Welders
Plasma Cutters
Air Compressors
Engine Driven Welders
Battery Power Supplies
Generators
Fume Extraction
Sub Arc Machines
Weld Positioning Equipment
Cutting Equipment
Spot Welders
Stud Welders
Used Machines
LC Laser Shop
ARC
MMA Electrodes
Cable Sets
Earth Clamps
Electrode Holders
Cable Connectors
Welding Cable
Welding Helmets
Arc Accessories
Rod Ovens
Learning
Exothermic Cutting
Chemical Aids
Gouging
MIG
MIG Filler Wire
MIG Torches & Parts
Site Wire Feeders
MIG Regulators
Ceramic Backing Tiles
MIG Accessories
TIG
TIG Torches
TIG Torch Parts
Tungsten Electrodes
TIG Filler Wire
Machine Remotes
TIG Accessories
Cold Wire Feeders
TIG Gauntlets
Tungsten Sharpening
Weld Cleaning
Gas Purging Tools
LASER
Laser Welders
Laser Cleaners
Laser Accessories
PLASMA
Plasma Torches
Plasma Torch Consumables
Lincoln Cutting Tables
GAS
Cutting & Welding Outfits
Gas Regulators
Flashback Arrestors
Gas Hoses & Fittings
Gas Torches
Gas Cutting Nozzles
Gas Welding & Heating Nozzles
Gas Accessories
Gas Welding & Brazing Rods
Gas Bottle Trolleys
Gas Cutting Machines
Quick Action Couplings
Regulator Accessories
Gas Analysers
SAFETY
Helmet Spares
Air Fed Welding Helmets
Swiss Air System
Goggles
Welding Blankets
Spectacles
Visors
Welding Curtains
Ear Protection
Safety Helmets
Monkey Masks
Gloves
Caps & Hoods
Leather Welding Clothing
Overalls
Weldline Female PPE
Disposable Masks & Respirators
WORKSHOP
Build your own GPPH Welding Table
Magnetic Drilling
Rapid Pipe Shop
Bevelling Machines
Automation
Metal Markers
Inspection Equipment
Pipework Equipment
Site Equipment
Exact Pipe Cutting Machines
Welding Rotators
Welding Tables
Bandsaws & Blades
TORCH &MACHINE SPARES
Pipe Cutting Machine Accessories
Parts for CO2 Laser
Kemppi MIG Parts
Machine Parts
Plasma Welding Torches
Water Coolers
Binzel MIG Parts
Tungsten Grinder Parts
WIRE, FLUX & RODS
Brazing Flux
Sub Arc Wire & Flux
ABRASIVES
3M Abrasives
SAIT Abrasives
Spectre Abrasives
Other Brand Abrasives
Backing Pads
Finishing & Polishing Products
Wire Brushes
Abrasive Belts
TOOLS
Angle Grinders
Right Lines Tool Offers
Magnetic Tools
Welding Clamps
Pipe Fit Up Tools
Site Storage
Orbitalum Pipe Machines
Orbitalum GF Sawblades
KNOWLEDGECENTRE
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Spares for a powered air welding helmet system: how to pick the right part, what wears, and how to keep the system working as intended.
Start with the data plate or label on the blower unit and helmet, then match what you find to the parts list in the user manual. The part number or marking on the old part is also a useful check, as is the type of filter fitted.Use the exact identifiers from your own equipment rather than guessing from appearance, because parts that look alike can differ in fit or performance. HSE guidance advises that replacement parts ideally come from the original manufacturer, so the equipment keeps working as it was approved to do. If you cannot match a part with confidence, ask before ordering.
On many powered welding respirators the air passes through a stack of layers before it reaches the wearer. A spark arrestor or filter cover usually sits at the front to stop hot particles reaching the filter media. A pre-filter usually catches coarse debris so the main filter does not clog as quickly. The particle filter is the part that removes fine fume and dust.The exact layout and which parts are fitted depend on the maker, so follow your manual for the order and for how each layer is fitted. Never run the unit with a layer left out unless the manual says that is allowed.
Change it as the manufacturer instructs, and sooner if it is damaged, visibly contaminated or has become harder to draw air through. For a powered unit that often shows up as a low airflow warning or a shorter battery run time. Do not use a filter that has passed its expiry date.HSE guidance suggests marking the filter with the date it was fitted, so you can add an in-house replacement date. Heavy fume or dust loading can clog a filter quickly, so there is no single safe interval that suits everyone. Your risk assessment and the manual set the routine.
No. A particle filter only removes solid and liquid particles such as welding fume and dust. It does not protect against gases or vapours, and a gas or vapour filter alone does not protect against particles. HSE guidance says never to use a particle-only filter against gas or vapour.If your work may expose you to gases, for example from certain coatings, cleaning solvents or shielding gases in a confined space, the right filter type and whether a powered filter unit is suitable at all should come from your risk assessment and the manufacturer, not from guesswork. Check what the filter markings say it protects against before you order a replacement.
Make an airflow check part of every pre-use check. HSE guidance says to check the fan is giving enough airflow before use, to confirm hoses are connected properly and to make sure battery-powered equipment is fully charged. Most makers describe a specific test, often using a flow indicator or by briefly covering the outlet to trigger the warning, so follow the method in your own manual.If the unit shows low flow, a blocked or loaded filter, a loose hose or a weak battery are the usual places to look. Do not start work until the unit passes.
Treat it as a stop signal. HSE guidance says never to keep working if the fan stops or the airflow rate drops, and to leave the work area immediately. Once you are out of the fume, look for the cause: a clogged or damaged filter, a kinked or disconnected hose, or a flat battery are the usual suspects.Only return to work when the system is giving the airflow the manufacturer specifies. If you cannot find a simple fix, withdraw the unit from use and have it checked by a competent person rather than carrying on with it.