0 items in your basket
Total £ 0.00 EX VAT
SHOPS
Special Buys/Offers
Rapid Merchandise Shop
PATON Shop
GoGrid Shop
GasiQ Shop
CK Shop
Furick TIG Shop
GPPH Shop
Kemppi Shop
Spiderhand Shop
Optrel Shop
3M Shop
Plymovent Fume Extraction
Miller Shop
Elga Shop
CEPRO Shop
Bohler Welding Shop
SFE Shop
Hypertherm Shop
Lincoln Electric Shop
ESAB Shop
Fronius Shop
HMT Shop
Gullco Shop
FEIN Shop
SAIT Shop
Harris Shop
FANUCI & FALCON Shop
Jackson Safety Shop
Key Plant Automation Shop
Orbitalum Shop
Bessey Shop
Bester Shop
EWM Shop
MACHINES
Welding Machine Offers
Arc Welders
MIG Welders
TIG Welders
Plasma Cutters
Air Compressors
Engine Driven Welders
Battery Power Supplies
Generators
Fume Extraction
Sub Arc Machines
Weld Positioning Equipment
Cutting Equipment
Spot Welders
Stud Welders
Used Machines
LC Laser Shop
ARC
MMA Electrodes
Cable Sets
Earth Clamps
Electrode Holders
Cable Connectors
Welding Cable
Welding Helmets
Arc Accessories
Rod Ovens
Learning
Exothermic Cutting
Chemical Aids
Gouging
MIG
MIG Filler Wire
MIG Torches & Parts
Site Wire Feeders
MIG Regulators
Ceramic Backing Tiles
MIG Accessories
TIG
TIG Torches
TIG Torch Parts
Tungsten Electrodes
TIG Filler Wire
Machine Remotes
TIG Accessories
Cold Wire Feeders
TIG Gauntlets
Tung Buddy
Tungsten Sharpening
Weld Cleaning
Gas Purging Tools
LASER
Laser Welders
Laser Cleaners
Laser Accessories
PLASMA
Plasma Torches
Plasma Torch Consumables
Lincoln Cutting Tables
GAS
Cutting & Welding Outfits
Gas Regulators
Flashback Arrestors
Gas Hoses & Fittings
Gas Torches
Gas Cutting Nozzles
Gas Welding & Heating Nozzles
Gas Accessories
Gas Welding & Brazing Rods
Gas Bottle Trolleys
Gas Cutting Machines
Quick Action Couplings
Regulator Accessories
Gas Analysers
SAFETY
Helmet Spares
Air Fed Welding Helmets
Swiss Air System
Goggles
Welding Blankets
Spectacles
Visors
Welding Curtains
Ear Protection
Safety Helmets
Monkey Masks
Gloves
Caps & Hoods
Leather Welding Clothing
Overalls
Weldline Female PPE
Disposable Masks & Respirators
WORKSHOP
Build your own GPPH Welding Table
Magnetic Drilling
Rapid Pipe Shop
Bevelling Machines
Automation
Metal Markers
Inspection Equipment
Pipework Equipment
Site Equipment
Exact Pipe Cutting Machines
Welding Rotators
Welding Tables
Bandsaws & Blades
TORCH &MACHINE SPARES
Pipe Cutting Machine Accessories
Parts for CO2 Laser
Kemppi MIG Parts
Machine Parts
Plasma Welding Torches
Water Coolers
Binzel MIG Parts
Tungsten Grinder Parts
WIRE, FLUX & RODS
Brazing Flux
Sub Arc Wire & Flux
ABRASIVES
3M Abrasives
SAIT Abrasives
Spectre Abrasives
Other Brand Abrasives
Backing Pads
Finishing & Polishing Products
Wire Brushes
Abrasive Belts
TOOLS
Angle Grinders
Right Lines Tool Offers
Magnetic Tools
Welding Clamps
Pipe Fit Up Tools
Site Storage
Orbitalum Pipe Machines
Orbitalum GF Sawblades
KNOWLEDGECENTRE
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
3m Workpiece Cable, Clamp & Electrode Holder - 140A.
Practical answers on the welding lead set and argon flowmeter that go with a small inverter welder.
A typical set has a return lead with a work clamp, and an electrode lead with an electrode holder. The holder grips the stick electrode and carries current to it. The clamp attaches to the workpiece, or to the bench it sits on, to complete the circuit back to the welder. The return lead is often wrongly called the earth lead.Both leads normally end in plugs that fit the sockets on the front of the welder. Check that the plug type, cable size and current rating suit your welder's data plate and the electrodes you plan to use.
Yes, it matters. The return clamp should connect directly to the workpiece, or to the bench it rests on, as close to the weld as practicable. Do not use rails, pipes or frames as part of the circuit unless they are part of the workpiece itself.Attach it to bright metal and remove rust or primer at the contact point, because a poor connection can overheat and arc. Faulty return paths can also let current stray through other conductors, so keep the return lead and clamp insulation in good condition.
Heat at a connection usually points to resistance in the circuit. Poor connections between electrode, holder and cable cause resistance heating that can overheat the holder, and clamps need a good contact to the workpiece to avoid overheating and arcing.Common causes are a clamp on rusty or painted metal, a worn clamp, a loose plug in the welder socket, a loose cable connection inside the holder, or a cable that is too small or damaged. Stop welding and let it cool before you investigate. Clean the contact point, check the plugs are fully seated, and replace any part that keeps overheating.
It depends on the electrode, not on the lead set. The electrode flux coating is the overruling factor, and the maker's polarity instructions on the electrode pack or data sheet decide it. Some electrodes are DC only, while others can run on either AC or DC.Polarity is changed by swapping which front socket each lead plugs into, always with the welder switched off. Electrode positive generally gives deeper penetration and electrode negative shallower penetration, but follow the electrode maker's instructions and your welding procedure rather than a general rule.