Fronius MHP 400i G Hose Packs FAQs
Straight answers about the lengths, handle options and everyday care of an air-cooled MIG hose pack.
What liner suits the wire I am using?

The liner guides the wire from the feeder to the torch, so it needs to suit both the wire type and its diameter. A spirally wound steel liner is normally used for hard wires such as steel and stainless steel, while a plastic (PTFE) liner is normally used for soft wires such as aluminium and copper.
Using the wrong type or size causes drag, poor feeding and wire damage. Check the hose pack's description and the maker's instructions for the liner that matches your wire before you order.
How do I choose the right contact tip for my wire?

The bore of the contact tip should be matched to the wire diameter. It needs to be slightly larger than the wire so that it feeds freely, but not so large that current pick-up suffers. A tip with an oversized or worn bore gives a poor connection and an unstable arc, so it should be replaced once the wear is excessive.
Tips made from harder-wearing copper alloys generally last longer, especially in spray and pulsed welding. Check the tip thread and size against the torch body fitted, and the data plate and manual if you are unsure.
How do I match the rating of a hose pack to my work?

Look at the highest current you will actually use and how long you will weld without a break. The duty cycle is the share of a ten-minute period for which the torch can run at its rated current without overheating, and running above it makes the handle and cable heat up, shortens the life of the consumables and can reduce weld quality.
Air-cooled torches rely on the surrounding air and the shielding gas to carry heat away, so they suit lighter to medium work. For high current and long runs at high duty cycles, a water-cooled torch is generally preferred. Two torches with the same current rating can have different duty cycles, so compare both figures.
Does the shielding gas change the rating of an air-cooled torch?

It can. Ratings are normally quoted for a stated gas, and some makers give a higher figure for carbon dioxide than for argon-based mixes because the gases cool the torch differently. Pulsed welding can also lower the usable rating. Other makers publish a single figure for both, so the only reliable answer is on the torch's data plate or in the maker's data sheet.
If you use a mixed gas or pulse, work from the figure given for those conditions, leave a good margin, and stop to let the torch cool if the handle or cable becomes uncomfortably hot.