Fronius MTW400i & MTB400i Parts FAQs
Straight answers about liners, seals, hoses and other spares for a water-cooled MIG torch, and how to pick the right ones.
Should I fit a steel liner or a plastic liner?

Match the liner to the wire. Steel liners are generally used for steel and stainless wire, while soft aluminium wire usually feeds better through a PTFE or other plastic-based liner, which reduces friction. The torch maker lists several liner types, including steel, coated steel, PTFE and combination designs, and matches the construction and bore to the welding process.
Going the other way is a mistake too: hard steel wire can cut into a soft plastic liner. Check the wire you will run, and the liner type your torch manual lists, before you order.
Do I need a new liner when I change wire size or type?

Usually yes, or at least check it. The liner is chosen to suit both the wire material and the wire diameter, and a liner that was right for one wire may not suit another. A bore much bigger than the wire lets it wander, and one that is too small makes it bind.
Liners are often colour-coded by wire size range, but the colours are not a universal standard, so read the packet and the torch manual. When you swap between steel and aluminium wire, change the liner type as well as the contact tip.
What do the O-rings in the torch do and when should I check them?

The O-rings seal the gas and coolant paths where parts join. A worn, cut or missing O-ring is listed by torch makers as a cause of porosity in the weld, and the fix is to replace it. One torch maker's troubleshooting table points to a cut or faulty O-ring on the central connector for porosity.
Look at them whenever you change a neck, a liner or the front-end parts, and replace any that are damaged. Use the O-ring type listed in your torch manual and parts list, as sizes differ between torches.
What should I check on the hoses and cable before welding?

The torch maker says to check all coolant connections for tightness, with no leaks, at every start-up, and to confirm that the coolant can flow unhindered. With the maker's cooling unit you can see a return flow in the coolant container, and the torch must never be run without coolant.
Check the wearing parts at every start-up too, and replace any that are faulty. Look along the hoses and cable for cracks, kinks or damage, and replace any damaged hose, fitting or cable before the torch is used again.