Zeta Fresh Air W201 w/ PFU PAPR Parts FAQs
Filters, covers, lenses and wear items for a powered air-purifying welding respirator, and how to work out the right ones.
When should I replace a cracked visor, cover lens or headtop?

Replace a visor or cover lens as soon as it is cracked or damaged, because a damaged one can hide further cracks and may no longer protect your face or eyes. Keeping visors clean helps you spot cracks early.
A helmet-style headtop should be replaced at the end of its service life, and it should be checked carefully after any heavy impact. If there is any damage or doubt, take it out of use and follow the maker's instructions on whether it must be replaced. Do not repair a damaged part with tape or adhesive.
What is the difference between particle filters and gas filters, and how do I read the colour bands?

A particle filter catches dust and fume, such as welding fume, but it does not remove gases or vapours. Gas filters are designed for particular gases, so they only help if they match the hazard you have identified.
Filter colour bands show what a filter protects against. Particle filters are white and marked P. Brown, grey, yellow and green bands cover different groups of gases and vapours, and combined filters carry more than one band plus a class number. For welding, which filter you need depends on the process, the metals and fumes involved and your risk assessment, so check this before you buy.
Is a powered respirator enough on its own to control welding fume?

Not necessarily. The HSE's welding guidance puts controlling fume at source first, usually with local exhaust ventilation, and uses respiratory protection where that cannot adequately control exposure. Outdoors, where extraction is impractical, suitable respiratory protection is needed.
For longer welding jobs the HSE points to battery-powered air-fed equipment with a minimum assigned protection factor of 20. Whether your equipment meets that is shown in the maker's marking and manual. Replacement parts must keep the unit within its approval, so use only what the maker specifies.
How do I work out which filter or spare part fits my unit?

Start with the data plate on the blower unit and the manual: they give the model or type, and the manual lists the approved filters, covers and other parts. Compare the part number or marking on the old part with what you are ordering.
Use only replacement parts specified by the maker. Substituting unapproved filters, seals or other parts can reduce the protection the unit gives and may invalidate its approval. If the part number is worn off, our team can help you match it from the unit details.