WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : 4,101,231  

    Fronius - ToolBox 300, XXL
    4,101,231

    £401.40  EX VAT
     Buy in 3 easy interest free payments of £133.80† with

    This Fronius ToolBox offers the possibility to create valuable storage space for welders’ various accessories and devices.

    Features

    • Can be retrofitted to almost all existing Fronius systems, see related items for more details
    • Offers storage space for wear parts, gloves, accessories, torches, electrode holders, ground cables and much more
    • Better to operate with a 50% increased operation height, especially for gas-cooled systems
    • Mountable with only four screws, which are included
    • Can be locked with any standard padlock
    • Maximum load of transport, 14Kg

    Please note that only one ToolBox can be used per system. Exception TU Car 2 (4,077,010), TU Car 2 Easy (4,077,019), TU Car 4 Standard (4,077,014) – only one cooling unit or one ToolBox may be used at one time due to the construction height. A water-cooled system with a ToolBox can only be used with TU Car 4 Pro. For this option, the Bottle Holder extension (4,101,075) is a necessity.

    Related Items

    iWave 300i AC / DC Water Cooled Parts FAQs

    Cooling units, cables, trolleys and add-ons for a water-cooled AC/DC TIG outfit: how to pick the right part and keep the cooled circuit healthy.

    How do I choose and look after the ground cable?icon-minus-redicon-plus-red

    Pick a cable and clamp rated for the current and duty cycle you will weld at, as stated in the manual, and make sure the connectors are clean, undamaged and correctly rated. The return clamp should be as near to the arc as possible, and welding and return leads should be insulated and thick enough to carry the current safely. Fix the clamp to clean bright metal, because rust or primer can cause overheating and arcing.

    Check the cable, clamp and plug before use. A damaged or loose return lead can cause burns, stray arcs and shock, so replace damaged cable rather than patching it with tape.

    What coolant should I use in the cooling unit?icon-minus-redicon-plus-red

    Use only the coolant that the cooling unit maker specifies, which is chosen for its electrical conductivity, frost protection and material compatibility. Never mix it with other coolants.

    Tap water is generally advised against, because minerals and algae can build up inside the torch and hoses. General automotive antifreeze is usually not recommended either, as it is not made for a small cooling loop. Check the level before welding while the system is cool, and follow the manual and the coolant safety data sheet when handling and changing it.

    How do I choose the right cooling unit?icon-minus-redicon-plus-red

    Match the cooling unit to the power source and the torch. Only approved system components should be connected to the cooling circuit, and the maker lists which cooling units suit which power sources, so check the manual or the data plate before choosing.

    Check the options too. Some units have optional extras such as a flow and temperature sensor, a level sensor or a coolant filter, which may need to be specified for your set-up. Also check that the unit suits your torch and that it fits on your trolley. If you are unsure, our team can help you work out the right match before you order.

    What can stop the coolant flowing, and what does the flow monitor do?icon-minus-redicon-plus-red

    Common causes are a low coolant level, a kinked or blocked hose, a dirty coolant filter, an air lock or a worn pump. At each start-up, watch for coolant returning to the container. If none returns, find and fix the cause before welding. Running water-cooled parts without coolant normally leads to failure of the system components.

    Some cooling units have an optional flow sensor that watches the coolant flow during welding, and it can warn you and then interrupt the welding current if flow falls too low. It is a safeguard, not a substitute for checking. If a warning keeps appearing, stop and find the cause, and follow the manual.