Straight answers to the questions people ask when choosing and running a MIG torch with built-in fume extraction.
When is a fume extraction MIG torch a good choice?

It suits MIG welding where you work at a bench or fixture, or move along a joint, and want the fume captured right at the arc. The extraction is built into the torch, so it travels with the weld rather than relying on you to keep repositioning a separate hood. The HSE says on-torch extraction can be very effective for MIG welding and is worth assessing for your task.
It works best on fairly open work in the flat or horizontal position. It is one part of your fume control, so check it against your risk assessment.
Is general workshop ventilation enough for mild steel fume?

No. The HSE states that exposure to all welding fume, including mild steel fume, can cause lung cancer, and that general ventilation does not achieve the necessary control. Indoors, the expected approach is suitable engineering control, typically local exhaust ventilation such as extraction at the torch or a well-placed hood.
If extraction alone does not control the exposure, the HSE says it should be supplemented with suitable respiratory protective equipment. Your risk assessment decides what is needed for your work.
When is on-torch extraction not a good fit?

It is less practical when the extraction openings cannot sit above the weld, because fume rises. The HSE gives welding overhead as an example, and says on-torch extraction is more effective on flat surfaces. It also cannot be relied on to capture fume outdoors, where the HSE says suitable respiratory protective equipment must be provided instead.
Awkward structures can also let some fume escape, because extraction does not capture every particle. In those cases other controls, such as a movable hood, general ventilation and respiratory protection, may be needed as well.
How often does the extraction system need testing?

The HSE says local exhaust ventilation must be thoroughly examined and tested at least every 14 months, by a competent person. For extraction at the torch, the HSE says capture velocity measurement is not appropriate, and the total airflow may instead be checked against the maker's recommended figure in the user manual. The torch, hose and filters also need regular maintenance checks, including visual inspection, with damaged or worn parts repaired or replaced.
Your risk assessment or the maker's instructions may call for checks more often if wear could quickly reduce performance. Keep the examiner's report, watch whether fume is being captured at the arc and report any change at once.
Should I choose an extraction torch or a movable extraction hood?

A movable hood on a swing arm relies on the welder placing it correctly and moving it as the work progresses, according to the HSE. An extraction torch keeps the capture point close to the arc automatically, which is why it suits repetitive or longer runs of MIG welding.
A hood can be easier for mixed work, awkward positions and processes other than MIG. Some workshops use both. Think about the joints you weld most, how often you move, and what space you have for the extraction unit.
How can I tell if the extraction is working properly day to day?

Most welding fume is easy to see, so the simplest check is to watch the arc. The HSE says to judge a system on how well it captures the fume, not just on airflow readings. If you can see fume drifting past the torch and up towards your face, capture is poor.
Also notice any drop in suction compared with normal, since a full filter is a common cause. Check the nozzle and hose first, then the unit's filter, following the maker's instructions. Do not carry on welding with weak extraction.